INSTALLATIONSfor EAZY EXTRAALLATION
ELECTRICS The unit must be installed to current electrical regulations with a fused spur mounted outside the room fused at 3 amps. We advise that this is done by a registered electrician.
WATER The unit is designed for a horizontal toilet with outlet the standard European 18 cm to the outlet centre from the floor. All other inlets must gravity fed into the unit. The outlet comes as standard with a 32 mm connection however 22 mm can be used with a reducer. What is very important is that the pipe run uses radius bends and not 90 degree bends as blockages can occur.
INPUTS The unit can used just for one input such as toilet or shower or sink or with all at once and blanking covers are provided to allow for this
SPECIFICATION Water Temperature minimum 1 degree centigrade it is important that the unit does not freeze and a maximum of 90 degrees
Motor power. A powerful 600 watts allows for all normal waste and is designed to give years of service
Voltage 230 volts at 50hz fused at 3 amp
Max discharge vertical 7 m
Max discharge horizontal 70m please see graph for more details
Flow rate the unit pumps at 240 litres per minute
DISPOSAL The unit is designed to give many trouble free years of service however at the end of its life be advised that the unit meets the current directive for disposal and must be handled in accordance with these standards.
FAULT FINDING
PROBLEM CAUSES SOLUTION
Motor humming but will not clear toilet or other sources Blockage in unit, something other than just tissue has blocked the motor or the outlet has become blocked 1. Disconnect from the electricity supply
2. Drain the toilet pan and unit using a siphon
3. Remove pan and check for obstruction inside by feeling
4. If nothing felt remove the lid of the unit
5. Remove large rubber tank and the motor as one unit
6. Remove motor by undoing clip from tank
7. Undo ring of screws from motor pump
8. Remove blockage
9. Reassemble in reverse of above.
10. Reconnect and check
Motor runs but stops and starts Blockage in outlet pipe Lift of lid and check the non return valve is not stuck open with any foreign material. Fit a short length of pipe on the outlet and run into bucket. Try the unit to see if it flushes correctly.
Motor silent Electric supply dead
Faulty Pressure switch Check the supply and replace fuse if required.
Press manual override button several times, motor should run. If nothing then suspect the motor
Pressure switch not working Faulty switch Check by removing the plastic pipe going to the switch and using a rubber ball create pressure. A click should be heard which indicates the switch is working and if the supply is connected the motor should run. It is possible for material to block the small plastic pipe so ensure it is clear.
ITEM DESCRIPTION
1 Outer case
2 Motor
3 Motor electrical connection
4 Capacitor
5 Pump gasket
6 Shaft seal
7 Pump and cutter impeller
8 Pump casing
9 Pipe clip
10 Outlet to waste pipes with built in non return valve
11 Supply cable
12 Supply cable gland
13 Manual over ride button
14 Pipe connector ( can use reducer)
15 Over ride switch nut
16 Pressure switch and pipe
17 Inner rubber tank
18 Pump casing fixing screws (10 off)
19 Pipe clip
This macerator has been extensively tested with some parts like the pressure switch being subjected to in excess of 30,000 operations to give a reliable maintenance free use. However the unit must be correctly installed and used in accordance to the makers instructions and only used for the disposal of water, tissue and human waste nothing else must be flushed through the unit